{"id":37,"date":"2017-03-16T15:48:23","date_gmt":"2017-03-16T15:48:23","guid":{"rendered":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/"},"modified":"2019-07-10T15:26:36","modified_gmt":"2019-07-10T15:26:36","slug":"metric-m-bolt-size-designation","status":"publish","type":"post","link":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/","title":{"rendered":"Metric &#8220;M&#8221; bolt size designation"},"content":{"rendered":"<p>By default, metric bolt sizes are not prefixed with the usual &#8220;M&#8221; designation:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-367\" src=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\" alt=\"\" width=\"500\" height=\"137\" srcset=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png 500w, https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi-300x82.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p>If you need the sizes shown with the M prefix you need to edit the isoconfig.xml.<\/p>\n<p>First, add a new units style called MetricBoltSize:<\/p>\n<p>&lt;Style Name=&#8221;MetricBoltSize&#8221; UnitFormat=&#8221;Decimal&#8221; Precision=&#8221;Precision1&#8243; Prefix=&#8221;M&#8221; Suffix=&#8221;&#8221; Scale=&#8221;1&#8243; Decimal=&#8221;.&#8221; \/&gt;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-369\" src=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201bb09843c84970d-500wi.png\" alt=\"\" width=\"500\" height=\"144\" srcset=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201bb09843c84970d-500wi.png 500w, https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201bb09843c84970d-500wi-300x86.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p>Then edit the BoltDiameterStyle so that the Metric option uses the MetricBoltSize size style created in the first step:<\/p>\n<p>&lt;BoltDiameterStyle Imperial=&#8221;ImperialSize&#8221; Metric=&#8221;MetricBoltSize&#8221; Rounded=&#8221;false&#8221; \/&gt;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-370\" src=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10833970b-500wi.png\" alt=\"\" width=\"500\" height=\"140\" srcset=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10833970b-500wi.png 500w, https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10833970b-500wi-300x84.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p>Now when creating the isometric, the BOM will display the bolt sizes with the M prefix:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-371\" src=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b8d26b6788970c-500wi.png\" alt=\"\" width=\"500\" height=\"127\" srcset=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b8d26b6788970c-500wi.png 500w, https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b8d26b6788970c-500wi-300x76.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>By default, metric bolt sizes are not prefixed with the usual &#8220;M&#8221; designation:<\/p>\n<\/p>\n<p>If you need the sizes shown with the M prefix you need to edit the isoconfig.xml.<\/p>\n<p>First, add a new units style called MetricBoltSize:<\/p>\n<p>&lt;Style Name=&#8221;MetricBoltSize&#8221; UnitFormat=&#8221;Decimal&#8221; Precision=&#8221;Precision1&#8243; Prefix=&#8221;M&#8221;<\/p>\n","protected":false},"author":26873,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[4],"tags":[],"class_list":["post-37","post","type-post","status-publish","format-standard","hentry","category-plant-3d"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Metric &quot;M&quot; bolt size designation - In the Pipes<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Metric &quot;M&quot; bolt size designation - In the Pipes\" \/>\n<meta property=\"og:description\" content=\"By default, metric bolt sizes are not prefixed with the usual &#8220;M&#8221; designation: If you need the sizes shown with the M prefix you need to edit the isoconfig.xml. First, add a new units style called MetricBoltSize: &lt;Style Name=&#8221;MetricBoltSize&#8221; UnitFormat=&#8221;Decimal&#8221; Precision=&#8221;Precision1&#8243; Prefix=&#8221;M&#8221;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/\" \/>\n<meta property=\"og:site_name\" content=\"In the Pipes\" \/>\n<meta property=\"article:published_time\" content=\"2017-03-16T15:48:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-07-10T15:26:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\" \/>\n<meta name=\"author\" content=\"Dan Scales\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dan Scales\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/\"},\"author\":{\"name\":\"Dan Scales\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/#\\\/schema\\\/person\\\/2d6b9b98759bf623545794bcc03bed08\"},\"headline\":\"Metric &#8220;M&#8221; bolt size designation\",\"datePublished\":\"2017-03-16T15:48:23+00:00\",\"dateModified\":\"2019-07-10T15:26:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/\"},\"wordCount\":102,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2017\\\/03\\\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\",\"articleSection\":[\"Plant 3D\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/\",\"url\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/\",\"name\":\"Metric \\\"M\\\" bolt size designation - In the Pipes\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2017\\\/03\\\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\",\"datePublished\":\"2017-03-16T15:48:23+00:00\",\"dateModified\":\"2019-07-10T15:26:36+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/#\\\/schema\\\/person\\\/2d6b9b98759bf623545794bcc03bed08\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2017\\\/03\\\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\",\"contentUrl\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2017\\\/03\\\/6a00d835007d0b69e201b7c8e10549970b-500wi.png\",\"width\":500,\"height\":137},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/2017\\\/03\\\/16\\\/metric-m-bolt-size-designation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Metric &#8220;M&#8221; bolt size designation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/#website\",\"url\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/\",\"name\":\"In the Pipes\",\"description\":\"Tips and Tricks from the Autodesk Product Support Team\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/#\\\/schema\\\/person\\\/2d6b9b98759bf623545794bcc03bed08\",\"name\":\"Dan Scales\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2019\\\/07\\\/DS-1.png\",\"url\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2019\\\/07\\\/DS-1.png\",\"contentUrl\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/wp-content\\\/uploads\\\/sites\\\/134\\\/2019\\\/07\\\/DS-1.png\",\"caption\":\"Dan Scales\"},\"description\":\"Dan studied Construction at Sheffield Hallam University and Building Surveying at Heriot Watt University in Edinburgh. Joining Autodesk in 2000, Dan has provided support for a wide variety of Autodesk products and has been supporting Plant and P&amp;ID since the very first releases. Prior to joining Autodesk, Dan gained experience working as a design draftsman for a number of consulting engineers in and around Edinburgh. Outside of work Dan enjoys riding motorcycles, road bikes and mountain bikes.\",\"url\":\"https:\\\/\\\/blogs.autodesk.com\\\/in-the-pipes\\\/author\\\/danscales\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Metric \"M\" bolt size designation - In the Pipes","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/","og_locale":"en_US","og_type":"article","og_title":"Metric \"M\" bolt size designation - In the Pipes","og_description":"By default, metric bolt sizes are not prefixed with the usual &#8220;M&#8221; designation: If you need the sizes shown with the M prefix you need to edit the isoconfig.xml. First, add a new units style called MetricBoltSize: &lt;Style Name=&#8221;MetricBoltSize&#8221; UnitFormat=&#8221;Decimal&#8221; Precision=&#8221;Precision1&#8243; Prefix=&#8221;M&#8221;","og_url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/","og_site_name":"In the Pipes","article_published_time":"2017-03-16T15:48:23+00:00","article_modified_time":"2019-07-10T15:26:36+00:00","og_image":[{"url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png","type":"","width":"","height":""}],"author":"Dan Scales","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Dan Scales"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#article","isPartOf":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/"},"author":{"name":"Dan Scales","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/#\/schema\/person\/2d6b9b98759bf623545794bcc03bed08"},"headline":"Metric &#8220;M&#8221; bolt size designation","datePublished":"2017-03-16T15:48:23+00:00","dateModified":"2019-07-10T15:26:36+00:00","mainEntityOfPage":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/"},"wordCount":102,"commentCount":0,"image":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#primaryimage"},"thumbnailUrl":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png","articleSection":["Plant 3D"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/","url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/","name":"Metric \"M\" bolt size designation - In the Pipes","isPartOf":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#primaryimage"},"image":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#primaryimage"},"thumbnailUrl":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png","datePublished":"2017-03-16T15:48:23+00:00","dateModified":"2019-07-10T15:26:36+00:00","author":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/#\/schema\/person\/2d6b9b98759bf623545794bcc03bed08"},"breadcrumb":{"@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#primaryimage","url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png","contentUrl":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2017\/03\/6a00d835007d0b69e201b7c8e10549970b-500wi.png","width":500,"height":137},{"@type":"BreadcrumbList","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/2017\/03\/16\/metric-m-bolt-size-designation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blogs.autodesk.com\/in-the-pipes\/"},{"@type":"ListItem","position":2,"name":"Metric &#8220;M&#8221; bolt size designation"}]},{"@type":"WebSite","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/#website","url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/","name":"In the Pipes","description":"Tips and Tricks from the Autodesk Product Support Team","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blogs.autodesk.com\/in-the-pipes\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/#\/schema\/person\/2d6b9b98759bf623545794bcc03bed08","name":"Dan Scales","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2019\/07\/DS-1.png","url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2019\/07\/DS-1.png","contentUrl":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-content\/uploads\/sites\/134\/2019\/07\/DS-1.png","caption":"Dan Scales"},"description":"Dan studied Construction at Sheffield Hallam University and Building Surveying at Heriot Watt University in Edinburgh. Joining Autodesk in 2000, Dan has provided support for a wide variety of Autodesk products and has been supporting Plant and P&amp;ID since the very first releases. Prior to joining Autodesk, Dan gained experience working as a design draftsman for a number of consulting engineers in and around Edinburgh. Outside of work Dan enjoys riding motorcycles, road bikes and mountain bikes.","url":"https:\/\/blogs.autodesk.com\/in-the-pipes\/author\/danscales\/"}]}},"_links":{"self":[{"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/posts\/37","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/users\/26873"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/comments?post=37"}],"version-history":[{"count":0,"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/posts\/37\/revisions"}],"wp:attachment":[{"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/media?parent=37"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/categories?post=37"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/in-the-pipes\/wp-json\/wp\/v2\/tags?post=37"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}