{"id":16290,"date":"2010-05-11T15:34:55","date_gmt":"2010-05-11T13:34:55","guid":{"rendered":"https:\/\/blogs.autodesk.com\/villagebim\/2010\/05\/pre-requis-systeme-pour-autocad-map-3d-2011.html"},"modified":"2010-05-11T15:34:55","modified_gmt":"2010-05-11T13:34:55","slug":"pre-requis-systeme-pour-autocad-map-3d-2011","status":"publish","type":"post","link":"https:\/\/blogs.autodesk.com\/villagebim\/2010\/05\/pre-requis-systeme-pour-autocad-map-3d-2011.html","title":{"rendered":"Pr\u00e9-requis syst\u00e8me pour AutoCAD Map 3D 2011"},"content":{"rendered":"<p>Vous savez sans doute que vous pouvez retrouver la m\u00eame information sur le <a href=\"http:\/\/www.autodesk.fr\/adsk\/servlet\/pc\/index?siteID=458335&amp;id=14672762\">site web Autodesk.fr, dans la section consacr\u00e9e \u00e0 Map 3D<\/a>, ainsi que dans la documentation du logiciel. <br \/>Cependant, je me rends compte qu\u2019il peut \u00eatre int\u00e9ressant de poster ici la configuration requise pour AutoCAD Map 3D 2011, et notamment les configurations de bases de donn\u00e9es support\u00e9es gr\u00e2ce \u00e0 FDO. <\/p>\n<p>Vous trouverez ci dessous les pr\u00e9-requis pour une installation sur un syst\u00e8me d\u2019exploitation 32 bits et une installation sur un syst\u00e8me d\u2019exploitation 64 bits.<\/p>\n<p>Je vous rappelle les points suivants : <br \/>&#8211; on ne peut pas installer la version 32 bits d\u2019AutoCAD Map 3D 2011 sur un syst\u00e8me d\u2019exploitation 64 bits <br \/>&#8211; on ne peut pas installer la version 64 bits d\u2019AutoCAD Map 3D 2011 sur un syst\u00e8me d\u2019exploitation 32 bits <br \/>&#8211; quand vous faites l\u2019acquisition d\u2019AutoCAD Map 3D 2011, vous recevez les kits d\u2019installation pour les syst\u00e8mes d\u2019exploitation 32 bits et 64 bits.<\/p>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td>Configuration mat\u00e9rielle et logicielle requise pour AutoCAD Map 3D 2011 <br \/>pour les <strong>syst\u00e8mes 32 bits<\/strong> <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td>Syst\u00e8mes d&#039;exploitation <\/td>\n<td>&#8211; Windows\u00ae XP Professionnel SP2 ou ult\u00e9rieur <br \/>&#8211; Windows Vista\u00ae Professionnel SP1 ou ult\u00e9rieur <br \/>&#8211; Windows Vista Ultimate SP1 ou ult\u00e9rieur <br \/>&#8211; Windows Vista Enterprise SP1 ou ult\u00e9rieur <br \/>&#8211; Windows 7 \u00c9dition Professionnel, Ultimate ou Enterprise<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Navigateur Web <\/td>\n<td>Internet Explorer\u00ae 7.0 ou version ult\u00e9rieure&#160;&#160;&#160; <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Processeur<\/td>\n<td>Windows XP : processeur double coeur Intel\u00ae Pentium\u00ae 4 ou AMD Athlon\u2122, 1,6 GHz ou sup\u00e9rieur dot\u00e9 de la technologie SSE 2 Windows Vista ou Windows 7&#160; : processeur double coeur Intel Pentium 4 ou AMD Athlon, 3,0 GHz ou sup\u00e9rieur dot\u00e9 de la technologie SSE2 <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>M\u00e9moire<\/td>\n<td>2 Go de RAM<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>R\u00e9solution de l&#039;affichage<\/td>\n<td>VGA 1 024 x 768 avec Couleurs vraies <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Support d\u2019installation<\/td>\n<td>DVD ou fichier t\u00e9l\u00e9charg\u00e9 (pas de support CD)<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Disque dur<\/td>\n<td>DVD : 3 Go pour l&#039;installation <br \/>Fichier t\u00e9l\u00e9charg\u00e9 : 6 Go pour l&#039;installation <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Logiciels facultatifs<\/td>\n<td>&#8211; Citrix XenApp 4.5 ou 5.0 <br \/>&#8211; FDO version 3.5 <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&#160;&#160;<\/p>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td>Configuration mat\u00e9rielle et logicielle requise pour AutoCAD Map 3D 2011 <br \/>pour les <strong>syst\u00e8mes 64 bits<\/strong> <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td>Syst\u00e8mes d&#039;exploitation <\/td>\n<td>&#8211; Windows\u00ae XP Professionnel SP2 ou ult\u00e9rieur <br \/>&#8211; Windows Vista\u00ae Professionnel SP1 ou ult\u00e9rieur <br \/>&#8211; Windows Vista Ultimate SP1 ou ult\u00e9rieur <br \/>&#8211; Windows Vista Enterprise SP1 ou ult\u00e9rieur <br \/>&#8211; Windows 7 \u00c9dition Professionnel, Ultimate ou Enterprise<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Navigateur Web <\/td>\n<td>Internet Explorer\u00ae 7.0 ou version ult\u00e9rieure&#160;&#160;&#160; <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Processeur<\/td>\n<td>&#8211; AMD Athlon 64 dot\u00e9e de la technologie SSE2 <br \/>&#8211; AMD Opteron\u2122 dot\u00e9e de la technologie SSE2 <br \/>&#8211; Intel Xeon\u00ae avec prise en charge d&#039;Intel EM64T et de la technologie SSE2 <br \/>&#8211; Intel Pentium 4 avec prise en charge d&#039;Intel EM64T et de la technologie SSE2 <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>M\u00e9moire<\/td>\n<td>4 Go de RAM<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>R\u00e9solution de l&#039;affichage<\/td>\n<td>VGA 1 024 x 768 avec Couleurs vraies <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Support d\u2019installation<\/td>\n<td>DVD ou fichier t\u00e9l\u00e9charg\u00e9 (pas de support CD)<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Disque dur<\/td>\n<td>DVD : 3 Go pour l&#039;installation <br \/>Fichier t\u00e9l\u00e9charg\u00e9 : 6 Go pour l&#039;installation <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Logiciels facultatifs<\/td>\n<td>&#8211; Citrix XenApp 4.5 ou 5.0 <br \/>&#8211; FDO version 3.5 <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&#160;&#160; Et sans doute tout aussi important, les versions support\u00e9es pour chaque fournisseur FDO :&#160;&#160;<\/p>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td>Configuration requise pour les fournisseurs FDO<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr valign=\"top\">\n<td width=\"132\">Microsoft SQL Server <\/td>\n<td width=\"333\">Microsoft SQL Server 2005 SP2 : \u00e9ditions Express, Standard et Enterprise <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">Microsoft SQL Server 2008<\/td>\n<td width=\"333\">Microsoft SQL Server 2008 SP1 : \u00e9ditions Express, Standard et Enterprise<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">Oracle 10g version 2<\/td>\n<td width=\"333\">Editions Oracle Express, Standard et Enterprise<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">Oracle 11g version 1<\/td>\n<td width=\"333\">Editions Oracle Express, Standard et Enterprise<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">Raster<\/td>\n<td width=\"333\">DEM, JPG2K, DTED, MrSID, ECW, PNG, ESRI Grid, TIFF, JPEG et ESRI ASCII<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">Autodesk SDF<\/td>\n<td width=\"333\">3.0<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">ESRI ArcSDE \/ ArcGIS Server<\/td>\n<td width=\"333\">ArcSDE 9.3 SP1 <a name=\"WS73099cc142f487552b5ac6c412649166e6e-481e\"><\/a><br \/>ArcSDE 9.2 (32 bits uniquement) <\/p>\n<p>Ce fournisseur exige que les composants sous licence ESRI soient install\u00e9s sur le syst\u00e8me client. Les composants requis d\u00e9pendent du type de connexion (service SDE ou connexion directe). <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">MySQL<\/td>\n<td width=\"333\">5.1.05<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">ODBC<\/td>\n<td width=\"333\">Voir tableau ci dessous<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">OGC WMS<\/td>\n<td width=\"333\">WMS 1.3.0<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">OGC WFS<\/td>\n<td width=\"333\">1.0.0<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">SQLite<\/td>\n<td width=\"333\">SQLite 3.6<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"132\">PostGreSQL<\/td>\n<td width=\"333\">PostGIS 1.4.0 sur PostgreSQL 8.4 <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Et enfin, les pilotes ODBC test\u00e9s (<a href=\"http:\/\/geospatialfrance.typepad.com\/geospatialfrance\/2010\/04\/odbc-dans-un-systeme-d-exploitation-64-bits.html\">attention, ceci est valable pour une installation 32 bits<\/a>) :<\/p>\n<table border=\"1\" cellpadding=\"2\" cellspacing=\"2\">\n<tbody>\n<tr>\n<td>Pilotes ODBC<\/td>\n<td>Versions test\u00e9es<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Pilote Microsoft Access (*.mdb, *.accdb) <\/td>\n<td><em>XP Pro SP3<\/em> &#8211; 12.00.6423.1000 <a name=\"WS73099cc142f487552b5ac6c412649166e6e-4818\"><\/a><em>Vista <\/em>&#8211; 6.00.6001.18000 <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Pilote Microsoft Excel (*.xls, *xlsx, *.xlsm, *.xlsb) <\/td>\n<td><em>XP Pro SP3<\/em> &#8211; 12.00.6423.1000 <a name=\"WS73099cc142f487552b5ac6c412649166e6e-4815\"><\/a><em>Vista <\/em>&#8211; 6.00.6001.18000 <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Pilote MySQL ODBC <\/td>\n<td>3.51.26<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Oracle <\/td>\n<td>10.2.0.2 ou 11.01.00.05<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Microsoft SQL Server 2005 Native Client <\/td>\n<td><em>XP et Vista<\/em> &#8211; 9.00.3042<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Microsoft SQL Server 2008 Native Client <\/td>\n<td><em>XP et Vista<\/em> &#8211; 10.00.1600.22<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>SQL Server <\/td>\n<td>2005.90.1399.00 <a name=\"WS73099cc142f487552b5ac6c412649166e6e-480e\"><\/a>2000.85.1117.00 <\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>SQL Server Native 10.0 <\/td>\n<td>2007.100.1602.22<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td>Pilote Microsoft Texte (*.txt, *.csv) <\/td>\n<td>4.00.6304.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Vous savez sans doute que vous pouvez retrouver la m\u00eame information sur le site web Autodesk.fr, dans la section consacr\u00e9e \u00e0 Map 3D, ainsi que dans la documentation du logiciel. Cependant, je me rends compte qu\u2019il peut \u00eatre int\u00e9ressant de poster ici la configuration requise pour AutoCAD Map 3D 2011, et notamment les configurations de [&hellip;]<\/p>\n","protected":false},"author":52098,"featured_media":2472,"menu_order":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[3377],"tags":[3472,1751,13,3498,3501,921,3499,3500,3141],"class_list":["post-16290","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-autocad-map-3d","tag-3472","tag-3d","tag-autocad","tag-configuration","tag-machine","tag-map","tag-pre","tag-recommandation","tag-requis","dhig-theme--light"],"acf":[],"_links":{"self":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts\/16290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/users\/52098"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/comments?post=16290"}],"version-history":[{"count":0,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts\/16290\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/media\/2472"}],"wp:attachment":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/media?parent=16290"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/categories?post=16290"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/tags?post=16290"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}