{"id":2210,"date":"2016-06-21T10:00:00","date_gmt":"2016-06-21T08:00:00","guid":{"rendered":"https:\/\/blogs.autodesk.com\/villagebim\/2016\/06\/insertion-de-modeles-revit-et-ifc-georeferences-dans-infraworks-360.html"},"modified":"2021-02-24T08:31:02","modified_gmt":"2021-02-24T06:31:02","slug":"insertion-de-modeles-revit-et-ifc-georeferences-dans-infraworks-360","status":"publish","type":"post","link":"https:\/\/blogs.autodesk.com\/villagebim\/2016\/06\/insertion-de-modeles-revit-et-ifc-georeferences-dans-infraworks-360.html","title":{"rendered":"Insertion de mod\u00e8les Revit et IFC g\u00e9or\u00e9f\u00e9renc\u00e9s dans InfraWorks 360"},"content":{"rendered":"<p>Le placement d\u2019une conception Revit dans InfraWorks 360 peut \u00eatre r\u00e9alis\u00e9 manuellement ou en exploitant les coordonn\u00e9es du point de base.<\/p>\n<p>Le premier cas correspond plut\u00f4t \u00e0 la recherche de l\u2019emplacement optimal d\u2019une proposition dans le contexte du site d\u2019accueil. Le second cas de l\u2019insertion pr\u00e9cise est davantage \u00e0 des fins de gestion, de communication et de validation du projet global.<\/p>\n<p>L\u2019approche d\u00e9crite est valable \u00e9galement pour les versions IFC des conceptions.<\/p>\n<p>Avant l\u2019insertion du mod\u00e8le dans InfraWorks 360 il faut savoir g\u00e9or\u00e9f\u00e9rencer le mod\u00e8le Revit et relever les coordonn\u00e9es du point de base d\u2019un mod\u00e8le g\u00e9or\u00e9f\u00e9renc\u00e9.<\/p>\n<p>&#160;<\/p>\n<p><span style=\"font-size: 18pt\">L\u2019attribution de coordonn\u00e9es au mod\u00e8le Revit<\/span><\/p>\n<p><strong>Autodesk\u00ae Shared Reference Point <\/strong>est un outil d\u00e9velopp\u00e9 sp\u00e9cifiquement pour cette manipulation. Son utilisation n\u2019est pas obligatoire mais facilite le processus en exploitant les capacit\u00e9s d\u2019AutoCAD Civil 3D pour les conceptions g\u00e9or\u00e9f\u00e9renc\u00e9es (gestion des syst\u00e8mes de coordonn\u00e9es) et en automatisant le transfert des informations vers Revit.<\/p>\n<p>Pour plus d\u2019information et savoir comment se procurer cet outil, vous pouvez consulter un article pr\u00e9c\u00e9dent <a href=\"http:\/\/civilfrance.typepad.com\/blog\/2015\/11\/g%C3%A9o-r%C3%A9f%C3%A9rencement-automatique-des-conceptions-revit.html\" rel=\"noopener noreferrer\" target=\"_blank\">ici<\/a>.<\/p>\n<p>Une vid\u00e9o illustre l\u2019exploitation de l\u2019outil <a href=\"https:\/\/knowledge.autodesk.com\/support\/revit-products\/learn-explore\/caas\/video\/youtube\/watch-v-di7zUR7jHBM.html\" rel=\"noopener noreferrer\" target=\"_blank\">ici<\/a>.<\/p>\n<p>&#160;<\/p>\n<p><span style=\"font-size: 18pt\">L\u2019insertion du mod\u00e8le Revit g\u00e9or\u00e9f\u00e9renc\u00e9 dans InfraWorks 360<\/span><\/p>\n<p><span style=\"font-size: medium\"><u>R\u00e9cup\u00e9ration des informations de g\u00e9or\u00e9f\u00e9rencement<\/u><\/span><\/p>\n<p>Il est n\u00e9cessaire de conna\u00eetre les coordonn\u00e9es du point de base du mod\u00e8le Revit et le syst\u00e8me de coordonn\u00e9es correspondant (souvent du Lambert 93 pour la France). Pour cela, depuis Revit, il faut afficher le point de base en activant les \u00e9l\u00e9ments cach\u00e9s. La fonction est disponible dans la barre de boutons en bas de l\u2019affichage Revit.<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01bb09143125970d-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-00-24\" border=\"0\" height=\"35\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0b41ad49.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-00-24\" width=\"423\" \/><\/a><\/p>\n<p>La vue Revit s\u2019adapte et fait apparaitre en magenta le point de base (il peut \u00eatre \u00e9loign\u00e9 du mod\u00e8le)<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01bb09143129970d-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-04-46\" border=\"0\" height=\"173\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0b6e42ed.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-04-46\" width=\"291\" \/><\/a><\/p>\n<p>En cliquent sur le point de base, les informations associ\u00e9es s\u2019affichent dans la vue et dans le panneau Propri\u00e9t\u00e9s :<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01bb0914312e970d-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-02-17\" border=\"0\" height=\"130\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0ba0c4af.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-02-17\" width=\"436\" \/><\/a><\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01bb09143133970d-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-02-52\" border=\"0\" height=\"154\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0bd45ea5.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-02-52\" width=\"438\" \/><\/a><\/p>\n<p>&#160;<\/p>\n<p><span style=\"font-size: medium\"><u>Dans InfraWorks 360<\/u><\/span><\/p>\n<p>Connecter le mod\u00e8le InfraWorks 360 au fichier Revit (ou IFC)<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01b8d1fa8ab9970c-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-12-13\" border=\"0\" height=\"316\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0c037fad.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-12-13\" width=\"290\" \/><\/a><\/p>\n<p>L\u2019\u00e9tape suivante, syst\u00e9matique pour toute donn\u00e9e connect\u00e9e, est la configuration.<\/p>\n<p>Dans l\u2019onglet \u201cEmplacement g\u00e9ographique\u201d, ne rien modifier dans le champ \u201cSyst\u00e8me de coordonn\u00e9es\u201d et saisir les informations du point de base dans le champ \u201cPosition\u201d.<\/p>\n<p><u>Remarques<\/u> :<\/p>\n<p>La valeur N\/S de Revit correspond au Y<\/p>\n<p>La valeur E\/O de Revit correspond au X<\/p>\n<p>L\u2019angle de Revit doit \u00eatre saisi en n\u00e9gatif dans le champ \u201cZ\u201d pour la Rotation dans InfraWorks 360<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01b8d1fa8ac3970c-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-24-05\" border=\"0\" height=\"545\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0c300140.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-24-05\" width=\"398\" \/><\/a><\/p>\n<p><strong>Fermer et actualiser<\/strong> la donn\u00e9e pour ins\u00e9rer la conception g\u00e9or\u00e9f\u00e9renc\u00e9e.<\/p>\n<p><a href=\"http:\/\/civilfrance.typepad.com\/.a\/6a0120a619192b970b01b7c870bdc9970b-pi\"><img loading=\"lazy\" decoding=\"async\" alt=\"2016-06-20_10-32-06\" border=\"0\" height=\"45\" src=\"https:\/\/blogs.autodesk.com\/villagebim\/wp-content\/uploads\/sites\/154\/2021\/02\/img_6035f0c71700a.jpg\" style=\"background-image: none;padding-top: 0px;padding-left: 0px;padding-right: 0px;border: 0px\" title=\"2016-06-20_10-32-06\" width=\"330\" \/><\/a><\/p>\n<p><strong>Remarque<\/strong> : dans certains cas de manipulations de la conception Revit, il peut y avoir un d\u00e9calage entre le point de base et la conception. Il faut alors ajouter les valeurs X, Y et Z n\u00e9cessaire pour prendre en compte ce d\u00e9calage dans InfraWorks 360 dans le champ \u201cD\u00e9calage\u201d \u00e0 droite du champ \u201cPosition\u201d.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Le placement d\u2019une conception Revit dans InfraWorks 360 peut \u00eatre r\u00e9alis\u00e9 manuellement ou en exploitant les coordonn\u00e9es du point de base. Le premier cas correspond plut\u00f4t \u00e0 la recherche de l\u2019emplacement optimal d\u2019une proposition dans le contexte du site d\u2019accueil. Le second cas de l\u2019insertion pr\u00e9cise est davantage \u00e0 des fins de gestion, de communication [&hellip;]<\/p>\n","protected":false},"author":1016,"featured_media":2472,"menu_order":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[3283],"tags":[],"class_list":["post-2210","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-civil-3d","dhig-theme--light"],"acf":[],"_links":{"self":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts\/2210","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/users\/1016"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/comments?post=2210"}],"version-history":[{"count":0,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/posts\/2210\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/media\/2472"}],"wp:attachment":[{"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/media?parent=2210"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/categories?post=2210"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.autodesk.com\/villagebim\/wp-json\/wp\/v2\/tags?post=2210"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}